AUTOMATIC FLASH AND FIRE POINT TESTER WITH BAROMETRIC CORRECTION OF THE RESULT
- The automated Cleveland Open Cup flash point tester accurately determines flash and fire point temperatures of viscous petroleum products including oils and bitumens
- The apparatus is a benchtop model which houses the mechanical components and a miniature PC with touch screen.
- Flash and fire point detection through ionization sensor: the apparatus also provides an alert if a flash has occurred at the first flame application, warning that the test result is not reliable.
- The flash point temperature remains shown on the display until the operator’s acknowledgement.
The instrument is equipped with a sensor for barometric pressure for the correction of the results towards atmospheric pressure.
Producător: Scavini
Model: AD0092-600
Cod: 8aada460a716
Preţ, fără TVA: La cerere
Telefon: 0744.594.794 / 0251.417.664
E-mail: tehnic@aparatura-laboratoare.ro
- The automated Cleveland Open Cup flash point tester accurately determines flash and fire point temperatures of viscous petroleum products including oils and bitumens
- The apparatus is a benchtop model which houses the mechanical components and a miniature PC with touch screen.
- Flash and fire point detection through ionization sensor: the apparatus also provides an alert if a flash has occurred at the first flame application, warning that the test result is not reliable.
- The flash point temperature remains shown on the display until the operator’s acknowledgement.
The instrument is equipped with a sensor for barometric pressure for the correction of the results towards atmospheric pressure.
Enamel finished steel case, benchtop version. | LAN connectivity, calibration and diagnostic routines. |
Electric heating plate. |
|
Brass oil cup with insulating handle (n°1 Pt100 with cable and quick connector supplied with the instrument). | Safety device is provided to stop the analyzer ifa flash has not been detected at a temperature 30°C over the preset value or at a temperature of 400°C. |
Electronically driven mechanism that passes the flame over the cup at the correct intervals for the correct amount of time | Dimensions (l x w x h): mm 360 x 460 x 680. Weight: kg 36 approx. |
Second generation ionization flash sensor. | ASTM D 92 - IP 36 - ISO 2592 |
Flame extinguisher: automatically extinguishes the flame covering the cup in case a fire is detected or after fire point detection. | CE marked |
PC based controller with touch-screen interface. | Selectable cooling time, storage of up to 400 test results andpossibility to retrieve and print test reports |
Selection of the ASTM/IP test method or setup of up to 40 custom methods |
|
Possibility to change thesetpoint during the test, “search” option |
|
|
|
Denumire accesoriu | COD | Pret Euro fara TVA |
Printer | AD0093-A00 |
|
PT100 simulator | CAL001 |
|
Officially certified PT100 simulator | CAL002 |
|